27758 Validation of distal limb mounted inertial measurement unit sensors for stride detection in Warmblood horses at walk and trot
Home Policy Brochure Browse Search User Area Contact Help

Braganca, F.M. and Bosch, S. and Voskamp, J.P. and Marin-Perianu, M. and van der Zwaag, B.J. and Vernooij, J.C. and van Weeren, P.R. and Back, W. (2016) Validation of distal limb mounted inertial measurement unit sensors for stride detection in Warmblood horses at walk and trot. Equine Veterinary Journal, online pre-publication. ISSN 2042-3306

Full text available as:

PDF

649 Kb
Open Access



Official URL: http://dx.doi.org/10.1111/evj.12651

Abstract

Background:
Inertial measurement unit (IMU) sensor-based techniques are becoming more popular in horses as a tool for objective locomotor assessment.

Objectives:
To describe, evaluate and validate a method of stride detection and quantification at walk and trot using distal limb mounted IMU sensors.

Study design:
Prospective validation study comparing IMU sensors and motion capture with force plate data.

Methods:
A total of seven Warmblood horses equipped with metacarpal/metatarsal IMU sensors and reflective markers for motion capture were hand walked and trotted over a force plate. Using four custom built algorithms hoof-on/hoof-off timing over the force plate were calculated for each trial from the IMU data. Accuracy of the computed parameters was calculated as the mean difference in milliseconds between the IMU or motion capture generated data and the data from the force plate, precision as the s.d. of these differences and percentage of error with accuracy of the calculated parameter as a percentage of the force plate stance duration.

Results:
Accuracy, precision and percentage of error of the best performing IMU algorithm for stance duration at walk were 28.5, 31.6 ms and 3.7% for the forelimbs and −5.5, 20.1 ms and −0.8% for the hindlimbs, respectively. At trot the best performing algorithm achieved accuracy, precision and percentage of error of −27.6/8.8 ms/−8.4% for the forelimbs and 6.3/33.5 ms/9.1% for the hindlimbs.

Main limitations:
The described algorithms have not been assessed on different surfaces.

Conclusions:
Inertial measurement unit technology can be used to determine temporal kinematic stride variables at walk and trot justifying its use in gait and performance analysis. However, precision of the method may not be sufficient to detect all possible lameness-related changes. These data seem promising enough to warrant further research to evaluate whether this approach will be useful for appraising the majority of clinically relevant gait changes encountered in practice.

Item Type:Article
Research Group:EWI-PS: Pervasive Systems
Research Program:CTIT-General
Uncontrolled Keywords:horse; inertial measurement unit; gait analysis; stride events; kinematics
ID Code:27758
Status:Published
Deposited On:30 March 2017
Refereed:Yes
International:Yes
More Information:statistics